Huawei CloudEngine CE6865E-48S8CQ
CE6865E-48S8CQ
Enterprise stock · tested · export documentation available
Huawei CloudEngine CE6865E-48S8CQ Data Center Switch – Product Documentation
Product Overview
The Huawei CloudEngine CE6865E-48S8CQ is a next-generation, high-performance Top-of-Rack (TOR) data center switch designed for high-density 25GE server access and 100GE uplink connectivity. It is part of the CloudEngine 6800 series and is engineered to meet the demanding requirements of cloud computing data centers and high-end campus networks.
This 1U switch features advanced hardware architecture with 48 x 25GE SFP28 downlink ports and 8 x 100GE QSFP28 uplink ports, delivering a forwarding performance of 2000 Mpps with L2/L3 line-rate forwarding . The QSFP28 ports offer flexible configuration options, capable of operating as a single 40GE QSFP+ port or being split into four 25GE SFP28 or 10GE SFP+ ports .
Powered by Huawei’s next-generation VRP8 operating system, the switch supports rich data center features including M-LAG (Multichassis Link Aggregation Group) for device-level redundancy, up to 16-unit stacking for scalability, and VXLAN hardware gateway capabilities for overlay network virtualization . The hardware supports flexible airflow direction (port-side intake or exhaust) and is optimized for all-flash storage networks with iLossless algorithms and NVMe Over Fabric+ (NOF+) architecture support .
The CE6865E-48S8CQ is ideally positioned for spine-leaf CLOS architectures in data centers, working seamlessly with Huawei CloudEngine 16800 or 12800 core switches to build elastic, virtualized 100GE fully-connected networks .
Product Specifications
| Category | Specification |
|---|---|
| Model | CE6865E-48S8CQ |
| Part Number | 02354CPN |
| Product Type | Data Center Switch (Managed L3) |
| Form Factor | 1U Rack-mountable |
Port Configuration
| Port Type | Quantity | Description |
|---|---|---|
| Downlink Ports | 48 x 10GE/25GE SFP28 | Supports 10GE or 25GE optical modules/cables |
| Uplink Ports | 8 x 40GE/100GE QSFP28 | Each port can be used as 1x40GE, or split into 4x25GE or 4x10GE |
Performance
| Parameter | Specification |
|---|---|
| Forwarding Performance | 2000 Mpps |
| Switch Capacity | 4 Tbps / 64 Tbps |
| Packet Buffer | 32 MB |
| MAC Address Table | 288,000 entries |
| Routing Table | 380,000 entries |
| ARP Table | 168,000 entries |
| VLANs | 4,063 |
| Multicast Groups | 32,000 |
| ACL Rules | 7,662 |
Physical Specifications
| Parameter | Specification |
|---|---|
| Dimensions (W x D x H) | 442.0 x 420.0 x 43.6 mm (17.4 x 16.5 x 1.72 in) |
| Weight | 8.8 kg (19.40 lb) |
| Chassis Color | Standard Huawei Data Center Switch |
Power Specifications
| Parameter | Specification |
|---|---|
| Power Supply Type | AC or DC, hot-swappable, 1+1 redundancy |
| AC Input Voltage Range | 90 V ~ 290 V (Rated: 100-240 V, 50/60 Hz) |
| DC Input Voltage Range | -38.4 V ~ -72 V |
| 240V HVDC Range | 190 V ~ 290 V |
| 380V HVDC Range | 190 V ~ 400 V |
| Maximum Power Consumption | 420 W |
| Typical Power Consumption | 259 W (100% throughput, all ports active) |
| Maximum Heat Dissipation | 1,433 BTU/hr |
| Typical Heat Dissipation | 884 BTU/hr |
Cooling System
| Parameter | Specification |
|---|---|
| Fan Modules | 4 x hot-swappable fan modules (1+1 backup) |
| Airflow Options | Port-side intake or port-side exhaust (model variant dependent) |
| Noise Level (27°C) | < 65 dBA |
| Hot-swappable | Yes (fan modules and power supplies) |
Environmental Specifications
| Parameter | Specification |
|---|---|
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
| Storage Temperature | -40°C to 70°C (-40°F to 158°F) |
| Operating Humidity | 5% to 95% RH, non-condensing |
| Maximum Altitude | < 5,000 m (16,404 ft) |
Port & Interface Details
| Interface Type | Description |
|---|---|
| Console Port | RJ-45 |
| Management Port | ETH management port (RJ-45) |
| USB Port | USB-based deployment support |
| Grounding Points | Front panel and rear chassis grounding terminals |
Software & Protocol Support
| Feature Category | Supported Protocols/Features |
|---|---|
| Stacking | Up to 16 units stacking, long-distance stacking via service port reuse |
| Link Aggregation | M-LAG (Multichassis Link Aggregation Group), device-level redundancy |
| VLAN | Access, Trunk, Hybrid, default VLAN, QinQ |
| QoS | Layer2/Layer3/Layer4 priority classification, ACL, CAR, PQ/DWRR/PQ+DWRR queuing, WRED, traffic shaping |
| Multicast | IGMP Snooping, IGMP Proxy, IGMP, PIM-SM, MBGP, multicast VLAN |
| Security | 802.1x authentication, DOS/ARP/ICMP attack prevention, port isolation, AAA/RADIUS/HWTACACS, IP-MAC-port-VLAN binding, RMON |
| Virtualization | VXLAN hardware gateway, BGP-EVPN control plane, support for 16M+ tenants |
| Advanced Features | MPLS, iLossless algorithms, NOF+ (NVMe Over Fabric+) architecture support |
| Management | CLI, SNMP, RMON, USB-based deployment |
Mounting & Serviceability
| Feature | Description |
|---|---|
| Mounting | Standard 19-inch rack mount with front, middle, and rear mounting bracket positions |
| Serviceability | All fan modules and power supplies are hot-swappable |
| Port Surge Protection | Built-in 6kV surge protection on ports |





















Reviews