Huawei CloudEngine S8700-4
S8700-4
Enterprise stock · tested · export documentation available
Huawei CloudEngine S8700-4 – Product Information
Product Overview
The Huawei CloudEngine S8700-4 is a next-generation modular aggregation/access switch designed specifically for premium campus networks in the Wi-Fi 6/7 era. As the smallest model in the CloudEngine S8700 series (alongside the S8700-6 and S8700-10), the S8700-4 features a 4-slot chassis configuration that includes 2 slots for Switch Routing Units (SRUs) and 2 slots for Line Processing Units (LPUs).
The switch delivers ultra-high densities of GE, 10GE, 25GE, 40GE, and 100GE access ports, enabling customers to quickly build future-proof campus networks with simplified architecture. All key components — including main control boards, power modules, and fan modules — adopt a redundancy design for carrier-grade reliability. The two SRUs work in active/standby mode for 1:1 hot standby, with the SRU in the smaller slot ID serving as the active unit by default.
The CloudEngine S8700-4 integrates native Wireless Controller (AC) functions and can manage up to 1,000 Access Points (APs) without the need for additional hardware ACs. It also supports advanced features including VXLAN L2 and L3 gateways, MACsec, comprehensive QoS policies, and IPv4/IPv6 dual-stack. With its highly scalable backplane supporting port bandwidth upgrades to 100 Gbit/s, the S8700-4 represents an ideal choice for aggregation and access nodes in cloud campus networks.
Technical Specifications
| Item | Specification |
|---|---|
| Model | S8700-4 |
| Part Number | 02116709-001 |
| Chassis Height | 5 U |
| Dimensions (H x W x D) without packaging | 219.5 mm x 442.0 mm x 475.1 mm (8.64 in. x 17.4 in. x 18.7 in.) — chassis body excluding mounting brackets |
| Dimensions (H x W x D) with mounting brackets | 219.5 mm x 482.6 mm x 577.3 mm (8.64 in. x 19 in. x 22.73 in.) |
| Dimensions with packaging (H x W x D) | 510 mm x 590 mm x 790 mm (20.08 in. x 23.23 in. x 31.10 in.) |
| Cabinet Installation Standards | A66E |
| Chassis Material | Metal |
| Weight without packaging | 23 kg (50.71 lb) |
| Weight without packaging (full configuration) | 42.72–44.28 kg (94.18–97.62 lb) |
| Number of SRU (MPU) Slots | 2 |
| Number of LPU (Service Board) Slots | 2 |
| Number of Power Slots | 6 |
| Number of Fan Modules | 1 |
| LPU Slot Direction | Horizontal |
| Switching Capacity | 2 Tbit/s |
| Port Density per Chassis | 144 x FE, 144 x GE, 144 x 10 GE, 40 x 25GE, 32 x 40/100GE |
| Redundant MPUs | Control unit and switching unit work in hot standby (1:1) mode |
| Redundant Power Supply | N+0, N+1, and N+N modes (N+1 mode recommended) |
| Redundant Fans | System can operate properly for a short time after a single fan fails |
| Rated Input Voltage | • DC input: -48 V DC/-60 V DC/48 V DC • AC input: 110 V AC/220 V AC, 50/60 Hz • High-voltage DC input: 240 V DC |
| Input Voltage Range | • DC input: -38.4 V DC to -72 V DC • AC input: 90–290 V AC; 45–65 Hz • High-voltage DC input: 190 V DC to 290 V DC |
| Maximum Power Consumption | 638 W (full configuration, without PoE) |
| Maximum Heat Dissipation | 2176.93 BTU/hour |
| Maximum Power Output Capability | • With six 1000 W AC power modules: 6000 W • With six 600 W DC power modules: 3600 W |
| MTBF | 35.17 years |
| Availability | 0.9999935084 |
| Noise at Normal Temperature (Acoustic Power) | • ≤ 69.5 dB(A) @ N+N power supply • ≤ 73.1 dB(A) @ N+1 power supply • ≤ 77.1 dB(A) @ N+0 power supply |
| Long-term Operating Temperature | –5°C to +45°C (23°F to 113°F) at altitude –60 m to +1800 m (–197 ft. to +5906 ft.) |
| Short-term Operating Temperature | –5°C to +55°C (23°F to 131°F) at altitude –60 m to 1800 m (–197 ft. to 5906 ft.) |
| First Supported Version | V600R024C10 |























Reviews